Micro Photography

PHOTOGRAPHY WITH CANON EOS R5 CAMERA LINKED WITH EOS UTILITY TO IMAC PRO WITH SEQUOIA 15.7.7 OPERATING SYSTEM VIA TETHER CABLE

The problem:

The internet is repeat with discussions and complaints of failure of these two systems to communicate. I finally solved the problem and it works perfectly.

The goal:

Link my Canon EOS R5 camera with the Olympus BH2/BHS microscope with seamless live view. That would include the opportunity to use the computer for visualizing the microscope subject without looking through the lens, adjust the camera settings and capture the exposure images remotely while using the controls on the computer.

History:

With earlier versions of the Canon EOS D5 and EOS Utility programs it did work. However, three things changed. I replaced the camera with an EOS 5R body, installed the latest iMac op-system Sequoia 15.7.7 upgrade and installed the latest matching Canon EOS Utility V.3.21.11. The communication was lost. The camera could not operate using the iMac communication protocol. I tried for nearly two years including repetitive installation of multiple versions of the Canon software and manipulation of permissions, firewalls, and op-system patches. I tried every variable communication option on the camera. Using Adobe Light I did have limited connection for transmitting one exposure to the computer but no live view and no control. I called the Canon tech support and their response was that they were not always able to keep up with the wide varieties of operating systems.

Solution:

Despite concerted efforts I could not connect the two devices wirelessly. Therefore, the most important step was to use a high-quality video tether cable. I used a Tether 15 foot cable dedicated to the camera. The computer is well within the cable length. I followed the cable instructions and connected the cable in the correct direction. I attached the computer picture cable end to the computer and the camera picture end to the camera.

Finally, without any patches and using only the EOS utility V.3.21.11 downloaded from the Canon website I was able to accomplish the desired result. I set the camera to three desired functions, I set ‘Function C-4’ to shoot without coupled lens, replaced the battery with a constant power connection, turned ‘auto shut down’ OFF, and set ‘electronic shutter’ ON. For additional information see the Canon manual.

Caution:

There are warnings in the ReadMe document attached to the downloaded installation package for the EOS Utility. If you lose connectivity or experience a power outage you may not be able to recover the connectivity without reinstalling the EOS Utility package. You will receive a message that states that you need to turn off any other communications with the camera or check to see that all cables are connected. This is not the issue. You must delete the application from your computer and reinstall it and restart the computer. Don’t delete the install software as you may need it again.

Close-up of orange Ethernet cables plugged into a black network switch
Fig 1. Tether connected to Canon R5 with cable stabilizer
Close-up of various audio and electronic cables plugged into a device, including a bright orange cable.
Fig 2. Tether connected to iMac Pro
Laboratory microscope connected to an iMac displaying a colorful scientific image
Fig 3. Olympus (BHS/BH2) connected to iMac Pro via Tether
Camera control panel software showing a full-screen image preview with an enlarged detail area and focus controls
Fig 4. Assembled composite image of Canon EOS Utility showing camera control panel, screen control panel, full screen and an enlarged area of a section of full screen area. Controls are self explanatory.

DISCUSSION:

By having the computer and microscope in close proximity this successful assembly of hardware and software permits easy control of exposure and composition of the viewing area. It enables full access to manually focus precisely while viewing a large screen. It also allows for manual adjustment of focus on fields of selected depth to make multiple exposures thus allowing later image-stacking software manipulation. This method may be helpful in other applications such as celestial photography. In future posts, you can see how this will work in the exploration of live marine behavior and coral with SCTLD using the Closed Cell Micro Aquarium.

If you like this please say so !

If you wish to receive notification of future posts please enter your email and click on Subscribe

Use the comments block below to help improve this site

#camera #microscope #Tether #EOS Utility #Canon R5 # micro photography

DIY Fiberoptic Illumination for Olympus BH2/BHS Microscope

FABRICATION OF A FIBEROPTIC SUPRASTAGE LIGHT SOURCE FOR THE BH2/BHS MICROSCOPE

Direct lighting for microscopic observation is important for subjects which do not transilluminate substage light. This DIY fiberoptic, suprastage, direct illuminator is designed to be low cost, easy to fabricate, install and maintain. The custom fabrication permits use of any of the visible spectrum of LED light sources including white light . This becomes especially useful when the required light source must be of a specific wavelength. In this instance the subject of interest has the property of biofluoresence. Green fluorescent protein (GFP) fluoresces with the application of royal blue light ~460nm. The light source shown here is one designed for provoking dinoflagellates to exhibit bioluminesence. The substage and direct light are matched in wavelength.

PROBLEM STATEMENT:

The microscopic observation of living coral for multiple days requires specific environmental controls that include temperature, light, nutrients, pH control, nitrate and phosphate regulation, and steady salt water flow rate. Additionally videography and stop motion time laps photography require complete lack of vibration and stable ambient temperature. This direct illumination is highly controlled. All heat sources are substantially distant from the microscope and there is no vibration. The direct light source is not attached to the microscope and any movement of the light or the stage does not affect one another.

This illuminator was developed in tandem with a LED for substage illumination. The Knapp BH2/BHS illuminator is described in a previous web posting . The paired illuminators are used for in-vivo bioluminescent studies. A future postings will describe the blocking filtration modification of the microscope.

List of materials;

  • Fiberoptic cable
  • Goose neck support
  • Barbed end plastic tubing connectors
  • Zip ties
  • Heat sink
  • Royal blue (~460nm) LED bulb
  • Inline resistor
  • Rosin core solder
  • Weighted end support
  • Power supply

Tools:

  • Soldering iron
  • Drill bit
  • Electric drill motor

POWER SOURCE:

Variable Power supply is available for purchase from the Empire of Dirt Workshop (empireofdirtworkshop.com) or contact Carl (carlh6902@gmail.com)

Disclaimer: I did not collaborate with Carl regarding the use of his power source. He makes his own design exclusively for Olympus BH2 microscopes. This illuminator is my design for BH2/BHS Olympus microscopes. I did fabricate a dual outlet extension cord which can be plugged into the LED outlet on the power supply. This allows for simultaneous dual illumination from one power source. The duplex container was fabricated from available PVD parts.

A black electronic device with a heatsink, connected to a cylindrical white component with wires on a grid background.
Power supply with Knapp duplex
A close-up image of a coiled black wire with two blue LED lights at either end, placed on a grid-patterned surface.
Fiberoptic cable, end glow, 5mm diameter, 1M length
A label from Mouser Electronics showcasing a product order, featuring details like item number, description of Cree single color LEDs, and a quantity of 20, alongside several blue LEDs attached to a brown card.
LED bulbs royal blue ~460nm.
Receipt for a purchase from Mouser Electronics, featuring carbon film resistors, including details such as part numbers and quantity.
One of two options for resistor choices needed to protect the LED.
A blue LED and a resistor connected by wires on a grid background.
Solder the resistor to the positive end of the LED and to the (+) side of the power supply.
A black flexible hose with a red lever and a clamp attachment, laid out on a grid background.
Stiff goose neck support modified by zip ties holding a series of plastic hose couplings. The cable was passed through the couplings
Close-up of a fiberoptic cable with a black rubber sheath, showing an end glow, and an LED with a resistor assembly double wrapped in heat shrink.
The LED is in direct contact with the fiberoptic cable
Close-up of a metallic component with grooves and a circular opening, set against a grid background.
Heat sink with central hole enlarged by drilling to fit the cables.
Close-up of a cable showing a heat sink and labeled connection points for optical and electrical connections.
Fiberoptic cable press fit end to end with the LED power cable held together by the heat sink.
Close-up of a black cable with electrical connectors, lying on a grid-patterned surface.
Completed optical and electronic transmission cable assembly.
Close-up of black tubing secured with zip ties to provide support for a fiberoptic cable.
The tubing allows the cable end to be advanced or retracted from the specimen.
A photo of a gooseneck light fixture, featuring a weighted stand, a power plug, and a light connection, with labels indicating each component.
Completed assembly of the Knapp fiberoptic illuminator. The weight stand is not specific but must be suitable to provide stability.
Close-up view of a microscope focusing on a glass slide illuminated by blue light.
Custom, closed cell, micro aquarium illuminated by the ~460nm light directed on the surface by the glow end of the fiberoptic cable.

Discussion:

The bulb/resistor assembly could have been compartmentalized to allow quick interchanging with alternative resources however at this time this combined unit is sufficient for the requirements of this project. Resistor may be exchanged to provide different brightness. The LED may be exchanged for different wavelength. I have not tried alternative wavelengths. Ultraviolet wavelengths might be interesting. The one meter length of fiberoptic cable probably could be shortened by 1/2 to reduce light transmission loss. I expect that this device would provide excellent direct illumination for nearly any standard microscope.

Resistor and Power Calculations:

A 5mm oval 460nm (blue) Cree C566E LED typically operates at a forward voltage (V_{f}\) of approximately 3.2V. To run it safely at a standard target current of 20mA (0.02A) from the 6V supply, use the following specifications:

Calculated resistance: (140 Ohm) Uses a standard 150 Ohm resistor.

Resistor Power Dissipation: The resistor will drop 2.8V at 0.02A, dissipating 0.056W. A standard 0.25W (1/4 watt) resistor is sufficient. (Note: While the power supply can deliver up to 2A, the resistor ensures the LED only draws the 20mA it requires). If the 20mA is not bright enough for fast shutter speed photography through the SPLAN 40 (which has a narrower aperture and requires more light), the Cree C566E lamp can tolerate power up to 30mA. To attain the 30mA Formula: Swap the resistor for a (100 Ohm) component. This increases brightness by 50% but will make the LED run slightly warmer. The included LED enclosure design is a small aluminum heatsink.

DIY cost not including power supply ~$30.00

#microscope #illuminator #light source #direct lighting #blue light #fiberoptic #bioluminescence

If you wish to be notified of future postings please enter you email and click on subscribe

Please feel free to comment. Don’t forget to like this post!